Houghtonmcbride2576

From DigitalMaine Transcription Project
Revision as of 15:24, 22 November 2024 by Houghtonmcbride2576 (talk | contribs) (Created page with "BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi-bend achromat storage ring. D...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi-bend achromat storage ring. Due to the low-emittance storage ring, BioMAX has a parallel, high-intensity X-ray beam, even when focused down to 20 µm × 5 µm using the bendable focusing mirrors. The beam is tunable in the energy range 5-25 keV using the in-vacuum undulator and the horizontally deflecting double-crystal monochromator. BioMAX is equipped with an MD3 diffractometer, an ISARA high-capacity sample changer and an EIGER 16M hybrid pixel detector. Data collection at BioMAX is controlled using the newly developed MXCuBE3 graphical user interface, and sample tracking is handled by ISPyB. The computing infrastructure includes data storage and processing both at MAX IV and the Lund University supercomputing center LUNARC. With state-of-the-art instrumentation, a high degree of automation, a user-friendly control system interface and remote operation, BioMAX provides an excellent facility for most macromolecular crystallography experiments. Serial crystallography using either a high-viscosity extruder injector or the MD3 as a fixed-target scanner is already implemented. The serial crystallography activities at MAX IV Laboratory will be further developed at the microfocus beamline MicroMAX, when it comes into operation in 2022. MicroMAX will have a 1 µm × 1 µm beam focus and a flux up to 1015 photons s-1 with main applications in serial crystallography, room-temperature structure determinations and time-resolved experiments.Inverse Compton scattering provides means to generate low-divergence partially coherent quasi-monochromatic, i.e. selleckchem synchrotron-like, X-ray radiation on a laboratory scale. This enables the transfer of synchrotron techniques into university or industrial environments. Here, the Munich Compact Light Source is presented, which is such a compact synchrotron radiation facility based on an inverse Compton X-ray source (ICS). The recent improvements of the ICS are reported first and then the various experimental techniques which are most suited to the ICS installed at the Technical University of Munich are reviewed. For the latter, a multipurpose X-ray application beamline with two end-stations was designed. The beamline's design and geometry are presented in detail including the different set-ups as well as the available detector options. Application examples of the classes of experiments that can be performed are summarized afterwards. Among them are dynamic in vivo respiratory imaging, propagation-based phase-contrast imaging, grating-based phase-contrast imaging, X-ray microtomography, K-edge subtraction imaging and X-ray spectroscopy. Finally, plans to upgrade the beamline in order to enhance its capabilities are discussed.The vacuum ultraviolet beamline BL03U with a photon energy range from 7 eV upwards has been constructed at the 3.5 GeV Shanghai Synchrotron Radiation Facility. Equipped with an APPLE-Knot undulator, this beamline is dedicated to angle-resolved photoemission spectroscopy. An energy-resolving power of higher than 4.6 × 104 has been achieved in the photon energy range 21.6-48 eV, which is almost the same as the theoretical estimation.An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10-10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al2O3/CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.Collagen is an important biomacromolecule, making up the majority of the extracellular matrix in animal tissues. Naturally occurring crosslinks in collagen stabilize its intermolecular structure in vivo, whereas chemical treatments for introducing synthetic crosslinks are often carried out ex vivo to improve the physical properties or heat stability of the collagen fibres for applications in biomaterials or leather production. Effective protection of intrinsic natural crosslinks as well as allowing them to contribute to collagen stability together with synthetic crosslinks can reduce the need for chemical treatments. However, the contribution of these natural crosslinks to the heat stability of collagen fibres, especially in the presence of synthetic crosslinks, is as yet unknown. Using synchrotron small-angle X-ray scattering, the in situ role of natural and synthetic crosslinks on the stabilization of the intermolecular structure of collagen in skins was studied. The results showed that, although natural crosslinks affected the denaturation temperature of collagen, they were largely weakened when crosslinked using chromium sulfate. The development of synergistic crosslinking chemistries could help retain the intrinsic chemical and physical properties of collagen-based biological materials.The pressure effects on atomic mean-square relative displacement characterizing the extended X-ray absorption fine structure (EXAFS) Debye-Waller factor of iron metal have been investigated based on the Debye model. The analytical expressions of the Debye frequency and EXAFS Debye-Waller factor have been derived as functions of crystal volume compressibility. Based on the well established equation-of-state including the contributions of the anharmonic and electronic thermal pressures, numerical calculations have been performed for iron up to a pressure of 220 GPa and compared with experimental data when possible. These results show that the Debye frequency increases rapidly with compression, and beyond 150 GPa it behaves as a linear function of pressure. Meanwhile the mean-square relative displacement curve drops robustly with pressure, especially at pressures smaller than 100 GPa. This phenomenon causes the enhancement of EXAFS signals at high pressure. Reversely, the increasing of temperature will reduce the amplitude of EXAFS spectra.