Howeburnett4864

From DigitalMaine Transcription Project
Jump to: navigation, search

54 cp/ml (interquartile range [IQR], 0.22 to 1.46 cp/ml) and a 14% (95% confidence interval [CI], 9% to 19%) decline in viral load for each additional year in duration suppressed. Within the RAVEN cohort, the expected false-negative rate for detection at lower rep numbers using 9 and 18 reps was 26% and 14%, respectively. Residual plasma viremia levels positively correlated with cell-associated HIV RNA and DNA. The performance characteristics of the replicate Aptima assay support its use for quantifying residual plasma viremia to study the latent HIV reservoir and cure interventions.Clearance of low-level viremia that persists in most HIV-1-positive individuals on antiretroviral therapy (ART) is an important milestone for efforts to cure HIV-1 infection. The level of persistent viremia on ART is generally below the lower limit of quantification (LOQ) of current FDA-cleared plasma HIV-1 RNA assays (20 to 40 copies/ml) but can be quantified by reverse transcriptase PCR (RT-PCR) assays with single-copy sensitivity. selleck inhibitor Such assays require multistep manual methods, and their low throughput limits the capacity to monitor the effects of interventions on persistent viremia. Recently, S. Bakkour, X. Deng, P. Bacchetti, E. Grebe, et al. (J Clin Microbiol 58e01400-20, 2020, https//doi.org/10.1128/JCM.01400-20), reported the use of multiple replicates and Poisson statistics to infer HIV-1 RNA concentrations below the commercial LOQ of an automated platform (Hologic Panther Aptima). Here, we evaluate the detection and quantitation of low-level viremia using the following two adaptions of the automated platform a multireplicate strategy (9×) and a concentrated single-replicate strategy in which 5 ml of plasma is concentrated by centrifugation (1×, concentrated). We compare these new methods to a recently reported manual integrase-targeting single-copy assay version 2 (iSCA v2). Using laboratory-generated HIV-1 RNA plasma samples at known concentrations, all three methods had similar sensitivity for HIV-1 RNA detection, although iSCA v2 was most sensitive (95% LOD, 2.3 copies/ml), 9× was marginally less sensitive (95% LOD, 3.0 copies/ml), and 1×, concentrated was least sensitive (95% LOD, 3.9 copies/ml). In contrast, for clinical plasma samples, 9× had greater sensitivity than iSCA v2 (82% of samples were quantifiable compared with 62% of samples by iSCA v2). These results support 9× as an acceptable high-throughput alternative to iSCA v2 for quantifying low-level viremia in individuals on ART.Seasonal influenza virus is associated with high morbidity and mortality especially in vulnerable patient populations. Here, we demonstrate the novel use of Sofia influenza A+B fluorescent immunoassay (FIA), a rapid antigen-based influenza point-of-care test (POCT), combined with Virena software for automatic deidentified tracking of influenza activity across the Los Angeles area and for predicting surges of influenza cases in the emergency department (ED). We divided outpatient clinics into 6 geographic zones and compared weekly influenza activity. In the outpatient setting, there were 1,666 and 274 influenza A and influenza B positives, respectively, across the 2018 to 2019 influenza season and 1,857 and 1,449 influenza A and influenza B positives, respectively, during the 2019 to 2020 influenza season, with zone-specific differences observed. Moreover, we found that a rapid increase in outpatient influenza was followed by an influx in influenza-positive cases in the ED, offering a 1- to 3-week warning sign for ED influx of triple or quadruple the number of influenza cases compared to the prior week. Sofia influenza A+B FIA allows for surveillance of real-time deidentified influenza activity. Tracking of such data may serve as a valuable region-specific influenza indicator and predictor to guide infection prevention measures in both the outpatient and hospital settings. High-impact interventions include designating areas for waiting rooms for influenza-like illnesses, altering staff scheduling in anticipation of surges, and securing sufficient personal protective equipment and antivirals during the height of influenza season.Mycoplasma hyopneumoniae is an economically significant pathogen of swine. M. hyopneumoniae serum antibody detection via commercial enzyme-linked immunosorbent assays (ELISAs) is widely used for routine surveillance in commercial swine production systems. Samples from two studies were used to evaluate assay performance. In study 1, 6 commercial M. hyopneumoniae ELISAs were compared using serum samples from 8-week-old cesarean-derived, colostrum-deprived (CDCD) pigs allocated to the following 5 inoculation groups of 10 pigs each (i) negative control, (ii) Mycoplasma flocculare (strain 27399), (iii) Mycoplasma hyorhinis (strain 38983), (iv) Mycoplasma hyosynoviae (strain 34428), and (v) M. hyopneumoniae (strain 232). Weekly serum and daily oral fluid samples were collected through 56 days postinoculation (dpi). The true status of pigs was established by PCR testing on oral fluids samples over the course of the observation period. Analysis of ELISA performance at various cutoffs found that the manufacturers' recommended cutoffs were diagnostically specific, i.e., produced no false positives, with the exceptions of 2 ELISAs. An analysis based on overall misclassification error rates found that 4 ELISAs performed similarly, although one assay produced more false positives. In study 2, the 3 best-performing ELISAs from study 1 were compared using serum samples generated under field conditions. Ten 8-week-old pigs were intratracheally inoculated with M. hyopneumoniae Matched serum and tracheal samples (to establish the true pig M. hyopneumoniae status) were collected at 7- to 14-day intervals through 98 dpi. Analyses of sensitivity and specificity showed similar performance among these 3 ELISAs. Overall, this study provides an assessment of the performance of current M. hyopneumoniae ELISAs and an understanding of their use in surveillance.Mycobacterium septicum is a rarely identified nontuberculous mycobacterium capable of causing infections in both healthy and immunocompromised individuals. Only a few cases of M. septicum infections have been reported, which makes recognizing corresponding clinical disease more challenging for clinicians. Antimicrobial susceptibility profiles for this organism are not well described, and corresponding optimal therapeutic regimens have not been established. We report a tertiary care center's experience with M. septicum from 2014 to 2020. Twelve adult patients with positive cultures for M. septicum were identified. Most cases were identified from sputum samples of individuals with underlying lung disease. Most cases involving M. septicum isolation in culture were not felt to be clinically significant. Two cases were considered possible infections, while only one case was considered a definite infection that required antimicrobial treatment. All M. septicum isolates were susceptible in vitro to amikacin, ciprofloxacin, imipenem, linezolid, moxifloxacin, and trimethoprim-sulfamethoxazole.